Description
DPBF2600A23060 – Contacteur 3 Pôles 230VAC 40A Lovato
DPBF2600A23060 – Contacteur 3 Pôles 230VAC 40A Lovato
Contacteur tétrapolaire , FLA 40A, AC bobine 60Hz, 230VAC
- Type de produit:
- Contacteurs
- Nombre de pôles:
- 3
- Type de bobine:
- Bobine AC 60Hz
- Tension nominale de la bobine [V]:
- 230
- Puissance pour la commande du moteur selon UL/CSA 480V [HP].:
- 30
- Type de contacts auxiliaires intégrés:
- 0
- Type de montage:
- Vis / rail DIN 35mm
https://catalogue.lovatoelectric.com/ca_fr/Contacteur-tetrapolaire-FLA-40A-AC-bobine-60Hz-230VAC/DPBF2600A23060/snp
- Fiche Technique
-
| Product designation |
|
Power contactor |
| Product type designation |
|
DPBF26 |
| Number of poles |
Nr. |
3 |
| Operational frequency |
|
|
min |
Hz |
25 |
|
|
max |
Hz |
400 |
| Operating position |
|
|
normal |
|
Vertical plan |
|
|
allowable |
|
±30° |
| Fixing |
|
Screw / DIN rail 35mm |
| Weight |
g |
420 |
| Mechanical life |
cycles |
20000000 |
| Electrical life |
cycles |
1600000 |
| Performance level B10d according to EN/ISO 13489-1 |
|
|
rated load |
cycles |
1600000 |
|
|
mechanical load |
cycles |
20000000 |
| Mirror contats according to IEC/EN 609474-4-1 annex F |
|
Yes |
| EMC compatibility |
|
yes |
| Rated AC voltage at 60Hz |
V |
230 |
| AC operating voltage |
|
of 60Hz coil powered at 60Hz |
|
|
pick-up |
|
|
|
|
min |
%Us |
80 |
|
|
max |
%Us |
110 |
|
|
drop-out |
|
|
|
|
min |
%Us |
20 |
|
|
max |
%Us |
55 |
| AC average coil consumption at 20°C |
|
of 60Hz coil powered at 60Hz |
|
|
in-rush |
VA |
75 |
|
|
holding |
VA |
9 |
| Dissipation at holding ≤20°C 50Hz |
W |
2.5 |
| Mechanical operation |
cycles/h |
3600 |
| Average time for Us control |
|
in AC |
|
|
Closing NO |
|
|
|
|
min |
ms |
8 |
|
|
max |
ms |
24 |
|
|
Opening NO |
|
|
|
|
min |
ms |
5 |
|
|
max |
ms |
15 |
|
|
Closing NC |
|
|
|
|
min |
ms |
9 |
|
|
max |
ms |
20 |
|
|
Opening NC |
|
|
|
|
min |
ms |
9 |
|
|
max |
ms |
17 |
| Rated operational voltage AC (UL) |
V |
600 |
| Full-load current (FLA) for three-phase AC motor |
|
|
at 600V |
A |
40 |
| Locked rotor current (LRA) |
A |
240 |
| Yielded mechanical performance |
|
for single-phase AC motor |
|
|
110/120V |
HP |
3 |
|
|
230V |
HP |
7.5 |
|
for three-phase AC motor |
|
|
200/208V |
HP |
10 |
|
|
220/240V |
HP |
10 |
|
|
460/480V |
HP |
30 |
|
|
575/600V |
HP |
30 |
| General USE |
|
Contactor |
|
|
AC current |
A |
45 |
| Short-circuit protection fuse, 600V |
|
High fault |
|
|
Short circuit current |
kA |
100 |
|
|
Fuse rating |
A |
100 |
|
|
Fuse class |
|
J |
|
Standard fault |
|
|
Short circuit current |
kA |
5 |
|
|
Fuse rating |
A |
100 |
| Temperature |
|
Operating temperature |
|
|
min |
°C |
-50 |
|
|
max |
°C |
70 |
|
Storage temperature |
|
|
min |
°C |
-60 |
|
|
max |
°C |
80 |
| Max altitude |
m |
3000 |
| Pollution degree |
|
3 |
| ETIM 8.0 |
|
EC000066 – Power contactor, AC switching |
Avis